The fans for Cement Industry are designed keeping in mind the need for:
- Higher efficiency
- Wear resistance
- Material build up and effects of erosion
- Variation of speed
- Low vibrations
- Stability in operation
- Retrofit solution
|
Application
- Raw Mill Fan
- Preheater Fan
- Bag House Fan
- Cooler ESP Fan
- Coal Mill Fan
- Coal Mill boaster Fan
- Separator Fan
- Cement Mill Fan
- Cooler Fan
General Information
- Impeller dia from 1 meter to 5.2 meter
- Flow up to 1000 cum/sec
- Pressure up to 27000 pa
- Different impeller profiles are chosen suiting different application
- Specially designed for dusty application
- Suitably designed for high temperature requirement
Reference List
Customer/ Enduser |
Application |
Fan Model |
Capacity(m3/S) |
Static Pressure (mm wg) |
Installed Motor Power(kW) |
| Satna Cement, Satna |
Kiln |
HF 4S TSR-338 3TS8A |
128 |
1400 |
2250 |
| Satna Cement, Satna |
Precalciner |
HF 2S SL-520-S8A |
85 |
870 |
1100 |
| Lafarge Cement, Sonadih |
Preheater |
HF-4S TDR-313-3TD8A |
179 |
866 |
2100 |
| Himambuja Cement, HP |
Raw Mill |
FI 8TDR-339-3TD-8A |
229 |
1300 |
4070 |
| Ultratech Cement, Hirmi |
Raw Mill |
HF 5S TD-298-3TD8A |
211 |
1020 |
3080 |
| Chettinad Cement, TN |
Raw Mill |
HF 5S TDR 303-3TD8A |
177 |
1150 |
3150 |
|
|
 |
|
|
|
|
 |
 |
|
|
|
|
 |
|
|
|
|